L130-6580HE1400001.pdf 데이터시트 (총 25 페이지) - 파일 다운로드 L130-6580HE1400001 데이타시트 다운로드

No Preview Available !

LUXEON 3014
Hot-color targeted industry standard
package for uniform light
LUXEON 3014 is an industry standard compatible footprint for ease
of installation into existing 3014 sockets and stays consistent with a
3.0mm x 1.4mm x 0.75mm package. LUXEON 3014 is hot-color targeted
at operating conditions—65°C. This low power device is an ideal
choice when uniformity and reduction in spottiness is necessary for
indoor designs.
Illumination
Features and Benefits
Industry standard footprint and package offering compatibility with
existing designs
1/9th ANSI micro-color binning enables tight color control
Hot-color targeted at 65°C which leads to better color accuracy
Rectangular package design allows for increased uniformity
Drive at maximum current, 120mA for superior value
Primary Applications
Indoor Area Lighting
Lamps
Specialty Lighting
–– Monochrome LED
–– Channel Lighting
–– Signage
DS208 LUXEON 3014 Product Datasheet ©2017 Lumileds Holding B.V. All rights reserved.
No. E352519
RoHS
COMPLIANT

No Preview Available !

Table of Contents
General Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Product Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Part Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Lumen Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Environmental Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Performance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Optical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical and Thermal Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Characteristic Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Spectral Power Distribution Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Light Output Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Forward Current Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Radiation Pattern Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Product Bin and Labeling Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Decoding Product Bin Labeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Luminous Flux Bins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Color Bin Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Forward Voltage Bins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Mechanical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Reflow Soldering Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
JEDEC Moisture Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Solder Pad Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Packaging and Labeling Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Pocket Tape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Reel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Moisture Barrier Bag (MBB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Shipment Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
DS208 LUXEON 3014 Product Datasheet 20170123 ©2017 Lumileds Holding B.V. All rights reserved.
i

No Preview Available !

General Product Information
Product Test Conditions
LUXEON 3014 LEDs are tested with a 20ms monopulse of 60mA at a junction temperature,Tj, of 25°C. Forward voltage and
luminous flux are binned at a Tj of 25°C, while color is hot targeted at a Tj of 65°C.
Part Number Nomenclature
Part numbers for LUXEON 3014 follow the convention below:
L130–AABBYY140000C
Where:
A A – designates nominal CCT (22=2200K, 25=2500K, 27=2700K, 30=3000K, 35=3500K, 40=4000K,
50=5000K, 57=5700K, 65=6500K, 80=8000K, 10=10000K)
B B – designates minimum CRI (70=70CRI, 80=80CRI, 90=90CRI)
Y Y – designates platform (HE=new generation for 80CRI, 00=previous generation)
C – designates Lumileds internal code (1 is full distribution base part; 2, 3, etc.=shares the same base part)
Therefore, the following part number is used for a new generation LUXEON 3014 3000K 80CRI:
L130–3080HE140000C
Lumen Maintenance
Please contact your local Sales Representative or Lumileds Technical Solutions Manager for more information about the long-
term performance of this product.
Environmental Compliance
Lumileds LLC is committed to providing environmentally friendly products to the solid-state lighting market. LUXEON 3014 is
compliant to the European Union directives on the restriction of hazardous substances in electronic equipment, namely the
RoHS Directive 2011/65/EU and REACH Regulation (EC) 1907/2006. Lumileds LLC will not intentionally add the following restricted
materials to its products: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated
diphenyl ethers (PBDE).
DS208 LUXEON 3014 Product Datasheet 20170123 ©2017 Lumileds Holding B.V. All rights reserved.
2

No Preview Available !

Performance Characteristics
Product Selection Guide
Table 1. Product performance of LUXEON 3014 at 60mA and 30mA at test temperature.
Nominal
CCT [1]
Minimum
CRI [2, 3, 4]
Luminous Flux [3] (lm)
Minimum
Typical
60mA
Typical
Luminous
Efficacy (lm/W)
Typical
Luminous
Flux (lm)
Typical
Luminous
Efficacy (lm/W)
30mA
Part Number
8000K
70
25
28
150 15 162 L130-8070001400001
10000K
70
23
27
145 14 151 L130-1070001400001
2200K
80
19
22
145 12 129 L130-2280HE1400001
2500K
80
21
24
140 12 129 L130-2580HE1400001
2700K
80
23
26
140 13 140 L130-2780HE1400001
3000K
80
23
26
140 13 140 L130-3080HE1400001
3500K
80
23
26
140 13 140 L130-3580HE1400001
4000K
80
25
28
150 15 161 L130-4080HE1400001
5000K
80
25
28
150 15 161 L130-5080HE1400001
5700K
80
25
28
150 15 162 L130-5780HE1400001
6500K
80
25
27
150 15 162 L130-6580HE1400001
2200K
90
16
18
97
9
99 L130-2290001400001
2700K
90
18
20
102 11 118 L130-2790001400001
3000K
90
19
20
102 11 118 L130-3090001400001
3500K
90
19
22
113 12 129 L130-3590001400001
4000K
90
20
23
113 12 129 L130-4090001400001
5000K
90
20
23
118 13 140 L130-5090001400001
5700K
90
20
23
118 13 140 L130-5790001400001
6500K
90
20
23
113
Notes for Table 1:
1. Correlated color temperature is hot targeted at Tj=65°C.
2. Lumileds maintains a tolerance of ±2 on CRI and ±6.5% on luminous flux measurements.
3. Typical CRI is approximately 2 points higher than the minimum CRI specified, but this is not guaranteed.
4. For 90CRI products, R9≥50.
12
129 L130-6590001400001
Optical Characteristics
Table 2. Optical characteristics for LUXEON 3014 at 60mA, Tj=25°C.
Part Number
Typical Total Included Angle [1]
L130-xxxxxx1400001
140°
Notes for Table 2:
1. Total angle at which 90% of total luminous flux is captured.
2. Viewing angle is the off axis angle from the LED centerline where the luminous intensity is ½ of the peak value.
Typical Viewing Angle [2]
116°
DS208 LUXEON 3014 Product Datasheet 20170123 ©2017 Lumileds Holding B.V. All rights reserved.
3

No Preview Available !

Electrical and Thermal Characteristics
Table 3. Electrical and thermal characteristics for LUXEON 3014 at 60mA, Tj=25ºC.
Part Number
Forward Voltage [1] (V)
Minimum Typical MAXIMUM
Typical Temperature
Coefficient of Forward
Voltage (mV/°C) [2]
L130-xxxxxx1400001
2.8 3.1
Notes for Table 3:
1. Lumileds maintains a tolerance of ±0.1V on forward voltage measurements.
2. Measured between 25°C and 85°C.
3.3
-2.0 to -4.0
Typical Thermal
Resistance—Junction
to Solder Pad (°C/W)
35
Absolute Maximum Ratings
Table 4. Absolute maximum ratings for LUXEON 3014.
Parameter
Maximum Performance
DC Forward Current [1,2]
120mA
Peak Pulsed Forward Current [1,3]
150mA
LED Junction Temperature [1] (DC & Pulse)
115°C
ESD Sensitivity (ANSI/ESDA/JEDEC JS-001-2012)
Class 2
Operating Case Temperature [1]
-40°C to 105°C
LED Storage Temperature
-40°C to 100°C
Soldering Temperature
JEDEC 020D 260°C
Allowable Reflow Cycles
3
Reverse Voltage (Vreverse)
-5V
Notes for Table 4:
1. Proper current derating must be observed to maintain the junction temperature below the maximum allowable junction temperature.
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple,” are acceptable if the following conditions are met:
– The frequency of the ripple current is 100Hz or higher
– The average current for each cycle does not exceed the maximum allowable DC forward current
– The maximum amplitude of the ripple does not exceed 15% of the maximum allowable DC forward current
3. At 10% duty cycle with pulse width of 10ms.
DS208 LUXEON 3014 Product Datasheet 20170123 ©2017 Lumileds Holding B.V. All rights reserved.
4