R05P209D.pdf 데이터시트 (총 6 페이지) - 파일 다운로드 R05P209D 데이타시트 다운로드

No Preview Available !

Features
Unregulated
Converters
• Qualified with 65kV/µs @ common mode =1KV
• Isolation 6.4kVDC
• Optional continuous short circuit protection
• Unique transformer system
• Compact SIP7 package
• /X2 version with >9mm input/output clearance
• very low isolation capacitance
DC/DC Converter
RxxP2xx
Description
The RxxP2xxS_D series of DC/DC converters are certified to UL/CSA60950-1 and UL/CSA62368-1 as
well as IEC/EN62368-1 and EN61010-1. This makes them ideal for medical and safety applications
where approved isolation is required. The /X2 version has an input/output clearance of more than 9mm.
Selection Guide
Part
Number
RxxP23.3S (3,4)
RxxP205S (3,4)
RxxP209S (3,4)
RxxP212S (3,4)
RxxP215S (3,4)
RxxP23.3D (3,4)
RxxP205D (3,4)
RxxP209D (3,4)
RxxP212D (3,4)
RxxP215D (3,4)
nom. Input
Output
Output Efficiency max. Capacitive
Voltage Voltage Current typ. (1) Load (2)
[VDC] [VDC] [mA] [%] [µF]
5, 12, 15, 24
3.3
600
70
3300
5, 12, 15, 24
5
400 70 - 75
1200
5, 12, 15, 24
9
222 70 - 75
1200
5, 12,15, 24
12
167 70 - 75
680
5, 12, 15, 24
15
133 75 - 80
680
5, 12, 15, 24
±3.3
±300
70
±1500
5, 12, 15, 24
±5
±200
70 - 75
±470
5, 12, 15, 24
±9
±111
70 - 75
±470
5, 12,15, 24
±12
±83 70 - 75
±330
5, 12, 15, 24
±15
±66 75 - 80
±330
2 Watt
SIP7
Single and Dual
Output
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max. Capacitive Load is defined as the capacitive load that will allow start up
in under 1 second without damage to the converter
Model Numbering
R__P2 __ _/P/X2
Input Voltage
Output Power
Output Voltage
Pinout (3)
Protection (4)
Single or Dual
E224736
EN/IEC62368-1 certified
UL/CSA60950-1 certified
UL/CSA62368-1 certified
EN61010-1 certified
EN55032 compliant
Notes:
Note3: add suffix „/X2“ for single output with alternative pinout
Note4: add suffix „/P“ for continous short circuit protection
Ordering Examples:
R05P205S/P = 5V Input, 5V Output, Single Output, Continous Short Circuit Protection
R05P23.3D/P = 5V Input, 3.3V Output, Dual Output, Continous Short Circuit Protection
R05P205S/P/X2 = 5V Input, 5V Output, Single Output, Continous Short Circuit Protection, Alternative Pinout
www.recom-power.com
REV.: 6/2018
www.recom-power.com/eval-ref-boards www.recom-power.com/bier
ECO-1

No Preview Available !

RxxP2xx
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Input Voltage Range
Minimum Load (5)
Internal Operating Frequency
Output Ripple and Noise (6)
Condition
20MHz BW
Min.
20kHz
Typ.
±10%
0%
50kHz
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
Note6: Measurements are made with a 0.1µF MLCC across output (low ESR)
Efficiency vs. Load
PxxP205S and PxxP209S
PxxP205D and PxxP209D
Max.
85kHz
200mVp-p
100
90
80
70
60
50
40
30 R05P205S
20 and R12P205S
R05P209S
10 R12P209S
0
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
PxxP212S and PxxP215S
100
90
80
70
60
50
40
30
20
10
0
0
R05P205D
and R12P205D
R05P209D
R12P209D
10 20 30 40 50 60 70 80 90 100
Output Load [%]
PxxP212D and PxxP215D
100
90
80
70
60
50
40
30 R05P212S
20 R12P212S
R05P215S
10 R12P215S
0
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
100
90
80
70
60
50
40
30
20
10
0
0
R05P212D
R12P212D
R05P215D
R12P215D
10 20 30 40 50 60 70 80 90 100
Output Load [%]
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Load Regulation
www.recom-power.com
Condition
low line to high line, full load
10% to 100% load
3.3, 5VDC
9, 12, 15VDC
continued on next page
REV.: 6/2018
Value
±5.0% max.
1.2%/1% of Vin typ.
15% typ.
10% typ.
ECO-2

No Preview Available !

DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Tolerance Envelope
RxxP2xx
Series
+10%
+5%
Vnom
Typical Load Line
+5%
-1.5%
-5%
10 50 100
Load [%]
Deviation vs. Load
PxxP205S and PxxP209S
25
20
15
10
5
0
-5
R05P205S
R05P209S
-10 R12P205S
R12P209S
-15
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
PxxP205D and PxxP209D
25
20
15
10
5
0
-5
-10
-15
0
R05P205D
R05P209D
R12P205D
R12P209D
10 20 30 40 50 60 70 80
Output Load [%]
90 100
PxxP212S and PxxP215S
25
20
15
10
5
0
-5
R05P212S
R05P215S
-10 R12P212S
R12P215S
-15
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
PxxP212D and PxxP215D
25
20
15
10
5
0
-5
-10
-15
0
R05P212D
R05P215D
R12P212D
R12P215D
10 20 30 40 50 60 70 80
Output Load [%]
90 100
www.recom-power.com
REV.: 6/2018
ECO-3

No Preview Available !

RxxP2xx
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
PROTECTIONS
Parameter
Type Value
Short Circuit Protection (SCP)
without Suffix “/P”
with Suffix “/P”
1 second
continuous
Isolation Voltage (7)
Isolation Resistance
I/P to O/P
tested for 1 second
rated for 1 minute
6.4kVDC
3.2VAC/60Hz
15Gmin.
Isolation Capacitance
1.5pF min. / 10pF max.
Insulation Grade
basic
Notes:
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note8: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T1A slow blow type
ENVIRONMENTAL
Parameter
Operating Temperature Range
Operating Altitude
Operating Humidity
Pollution Degree
MTBF
Derating Graph
(@ Chamber and free air convection)
www.recom-power.com
Condition
without derating @ free air convection (see graph)
non-condensing
according to MIL-HDBK-217F, G.B.
+25°C
+85°C
Single
Dual
Single
Dual
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
Ambient Temperature [°C]
95
REV.: 6/2018
Value
-40°C to +90°C
2000m
95% RH max.
PD2
2113 x 103 hours
2434 x 103 hours
299 x 103 hours
334 x 103 hours
ECO-4

No Preview Available !

DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Information Technology Equipment, General Requirements for Safety
Audio/video, information and communication technology equipment.
Safety requirements
Audio/video, information and communication technology equipment.
Safety requirements
Safety Requirements for Electrical Equipment for Measurement,
Control and Laboratory Use - Part 1: General Requirements
EAC
RoHs 2+
Report / File Number
E224736-A56-UL
E224736-A56-UL
ATTCB106076
PS080601010
RU-AT.49.09571
EMC Compliance
Electromagnetic compatibility of multimedia equipment -
Emission requirements
Condition
with external filter
EMC Filtering Suggestions according to EN55032 Class A and Class B
RxxP2xx
Series
Standard
UL60950-1, 2nd Edition, 2014
CAN/CSA C22.2 No. 60950-1, 2nd Edition, 2014
UL62368-1, 2nd Edition, 2014
CAN/CSA C22.2 No. 62368-1, 2nd Edition, 2014
IEC62368-1:2014, 2nd Edition
EN62368-1:2014 +A11:2017
EN61010-1:2010
TP TC 004/2011
RoHS-2011/65/EU + AM2015/863
Standard / Criterion
EN55032, Class A/B
L1
+VIN
C1
-VIN
C2
Component List Class A
C3
+VOUT
C1
10µF+1V00INV MLCC
L1
L1
-
C3C3
- +VOUT
Component List Class B
C1 C1 C1 C2
L1
COM
C3
-VOUT
10µF-1V0IN0V
10µF 100V
470µH choke
2n2F 8kV-VOUT
MLCC
MLCC WE 744 045 120 Vishay HGZ222MBP
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Material
Package Dimension (LxWxH)
Package Weight
www.recom-power.com
Type
case
potting
PCB
continued on next page
REV.: 6/2018
Value
non-conductive black plastic, (UL94 V-0)
silicon rubber compound, (UL94 V-0)
FR4, (UL94 V-0)
19.5 x 9.8 x 12.5mm
4.3g typ.
ECO-5