SLC03.pdf 데이터시트 (총 4 페이지) - 파일 다운로드 SLC03 데이타시트 다운로드

No Preview Available !

SLC03 & DLC033W DIP Package DC-DC Regulated Converter
series
Features
DIP16 package with industry standard pinout
2:1 wide input range
Operating temperature range -40 ~ +85
No minimum load required
Comply to EN55032 radiated Class B without additional
components
High efficiency up to 82%
Protections: Short circuit (Continuous) / Overload /
Input under voltage
1.5KVDC I/O isolation
3 years warranty
Applications
Telecom/datacom system
Wireless network
Industrial control facility
Instrument
Analyzer
Detector
Data switch
Description
SLC03 and DLC03 series are 3W isolated and regulated module type DC-DC converter with DIP16 package.
It features international standard pins, a high efficiency up to 82%, wide working temperature range
-40~+85, 1.5KVDC I/P-O/P isolation voltage, the compliance to EN55032 radiated Class B without
additional components, continuous-mode short circuit protection, etc. The models account for different
input voltage, 9~18V, 18~36V and 36~75V 2:1 wide input range, and various output voltage, 5V/12V/
15V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for all kinds of systems,
such as industrial control, telecommunication field, distributed power architecture, and so on.
Model Encoding
S LC03 A - 12
Output voltage (5/12/15Vdc±5/±12/±15Vdc)
Input voltage (A: 9~18VdcB: 18~36VdcC: 36~75Vdc)
Rated wattage
{Series name
S:Single output
D:Dual output
File Name:SLC03,DLC03-SPEC 2017-02-24

No Preview Available !

SLC03 & DLC033W DIP Package DC-DC Regulated Converter
series
MODEL SELECTION TABLE
INPUT
ORDER NO.
INPUT VOLTAGE
(RANGE)
INPUT CURRENT
NO LOAD
FULL LOAD
SLC03A-05
25mA
330mA
SLC03A-12
15mA
320mA
SLC03A-15
DLC03A-05
12V
(9 ~ 18V)
15mA
30mA
309mA
325mA
DLC03A-12
32mA
305mA
DLC03A-15
32mA
313mA
SLC03B-05
10mA
154mA
SLC03B-12
10mA
154mA
SLC03B-15
DLC03B-05
24V
(18 ~ 36V)
10mA
20mA
153mA
158mA
DLC03B-12
20mA
156mA
DLC03B-15
20mA
156mA
SLC03C-05
7mA 77mA
SLC03C-12
7mA 76mA
SLC03C-15
DLC03C-05
48V
(36 ~ 75V)
7mA
10mA
76mA
79mA
DLC03C-12
10mA
78mA
DLC03C-15
10mA
78mA
OUTPUT
OUTPUT
VOLTAGE
OUTPUT
CURRENT
EFFICIENCY CAPACITOR LOAD
(TYP.)
(MAX.)
5V
12V
15V
±5V
±12V
±15V
5V
12V
15V
±5V
±12V
±15V
5V
12V
15V
±5V
±12V
±15V
600mA
250mA
200mA
±0 ~ 300mA
±0 ~ 125mA
±0 ~ 100mA
600mA
250mA
200mA
±0 ~ 300mA
±0 ~ 125mA
±0 ~ 100mA
600mA
250mA
200mA
±0 ~ 300mA
±0 ~ 125mA
±0 ~ 100mA
79% 1000μF
81% 470μF
81% 330μF
79% * 220μF
82% *220μF
81% *220μF
81% 1000μF
82% 470μF
82% 330μF
79% *220μF
81% *220μF
80% *220μF
81% 1000μF
82% 470μF
82% 330μF
80% *220μF
80% *220μF
80% *220μF
* For each output
File Name:SLC03,DLC03-SPEC 2017-02-24

No Preview Available !

SLC03 & DLC033W DIP Package DC-DC Regulated Converter
series
SPECIFICATION
VOLTAGE RANGE
A: 9~18Vdc , B: 18~36Vdc , C: 18~75Vdc
SURGE VOLTAGE (100ms max.) 12Vin models : 25Vdc ; 24Vin models : 50V ; 48Vin models : 100Vdc
INPUT
FILTER
Internal capacitor
PROTECTION
Fuse recommended. 12Vin models: 1A Slow-Blow Type, 24Vin models: 0.5A Slow-Blow Type, 48Vin models: 200mA Slow-Blow Type
INTERNAL POWER DISSIPATION 1000mW
VOLTAGE ACCURACY ±2%
RATED POWER
3W
OUTPUT
RIPPLE & NOISE Note.2 50mVp-p
LINE REGULATION Note.3 ±0.2%
LOAD REGULATION Note.4 ±0.5%
SWITCHING FREQUENCY (Typ.) 100KHz
SHORT CIRCUIT
Protection type : Continuous, automatic recovery
OVERLOAD
PROTECTION
150 ~ 250% rated output power
Protection type : Recovers automatically after fault condition is removed
Start-up voltage
UNDER VOLTAGE LOCKOUT
Shutdown voltage
COOLING
Free-air convection
12Vin: 8.8Vdc, 24Vin: 17Vdc, 48Vin: 34Vdc
12Vin: 7Vdc, 24Vin: 14Vdc, 48Vin: 30Vdc
WORKING TEMP.
CASE TEMPERATURE
-40 ~ +85(Refer to "Derating Curve")
+100max.
WORKING HUMIDITY 20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +105, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
0.03% / (0 ~ 80)
SOLDERING TEMPERATURE 1.5mm from case of 3 ~ 5sec./265max.
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
WITHSTAND VOLTAGE I/P-O/P:1.5KVDC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
ISOLATION CAPACITANCE (Typ.) 80pF
Parameter
Standard
Test Level / Note( Note.6)
EMC EMISSION
Conducted
EN55032(CISPR32)
N/A
SAFETY &
EMC
( Note.5)
Radiated
Parameter
ESD
EN55032(CISPR32)
Standard
EN61000-4-2
Class B
Test Level / Note
Level 3, ±8KV air ; Level 2, ±4KV contact
EMC IMMUNITY
Radiated Susceptibility
EFT/Burest
EN61000-4-3
EN61000-4-4
Level 2, 3V/m
Level 1, 0.5KV at power
Surge
EN61000-4-5
Level 2, 0.5KV Line-Line
Conducted
EN61000-4-6
Level 2, 3V(e.m.f.)
Magnetic Field
EN61000-4-8
Level 1, 1A/m
MTBF
300Khrs min. MIL-HDBK-217F(25)
OTHERS
NOTE
DIMENSION (L*W*H)
22.1*13.8*8.55mm (0.87*0.54*0.34 inch)
CASE MATERIAL
Non-Conductive black plastic (UL 94V-0 rated)
PACKING
4.5g
1.All parameters are specified at normal input(A:12Vdc, B:24Vdc, C:48Vdc), rated load, 2570% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please
refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
6.An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: 220uF/100V.
File Name:SLC03,DLC03-SPEC 2017-02-24

No Preview Available !

SLC03 & DLC033W DIP Package DC-DC Regulated Converter
series
Mechanical Specification
All dimensions in mm(inch)
Tolerance:x.x±0.5mm(x.xx±0.02")
x.xx±0.25mm(x.xxx±0.01")
Pin size is 0.50x0.30mm (0.02"x0.01")
Pin is Tolerance:x.xx±0.07mm(x.xxx±0.03")
1.77(0.07)
1
16
22.1(0.87)
78
Bottom View
10 9
0.5(0.02)
22.1(0.87)
Side View
2.16(0.09)
15.24(0.6)
2.54(0.1)
Plug Assignment
Pin No.
1
7
8
9
10
16
Pin-Out
SLC03
DLC03
(Single output) (Dual output)
-Vin
N.C.
N.C.
+Vout
-Vout
+Vin
-Vin
N.C.
Common
+Vout
-Vout
+Vin
Derating Curve
100
80
60
50
40 Natural convection
20
-40 -20 0 20 40 60
Ta ()
71 85 100
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:SLC03,DLC03-SPEC 2017-02-24