Features
Efficiency up to 85%
1500VDC Isolation
Singl/Double output
Continous short circuit protection
Over load protection
Wide input voltage range 2:1/4:1)
Wide temperature -40 to 85
Low ripple and noise
DD(F)10 Series
10W
Model Selection Guide
Order Code
DD10-05S05
DD10-05S12
DD10-12S3V3
DD10-12S05
DD10-12S12
DD10-12S15
DD10-12S24
DD10-12D05
DD10-12D12
DD10-12D15
DD(F)10-24S3V3
DD(F)10-24S05
DD(F)10-24S12
DD(F)10-24S15
DD(F)10-24S24
DD(F)10-24D05
DD(F)10-24D12
DD(F)10-24D15
DD(F)10-48S3V3
DD(F)10-48S05
DD(F)10-48S12
DD(F)10-48S15
DD(F)10-48S24
DD(F)10-48D05
DD(F)10-48D12
DD(F)10-48D15
DD10-110S05
DD10-110S12
DD10-110S24
DD10-110D05
DD10-110D12
Vin(V)
Nominal
Range
5 4.5-9.0
12 9-18
18-36
24 (F)9-36
36-72
48 (F)18-72
110 60-160
Output
Vo(V)
Io(mA)
5 2000
12 833
3.3 3000
5 2000
12 833
15 667
24 417
+5 +1000
+12 +417
+15 +333
3.3 3000
5 2000
12 833
15 667
24 417
+5 +1000
+12 +417
+15 +333
3.3 3000
5 2000
12 833
15 667
24 417
+5 +1000
+12 +417
+15 +333
5 2000
12 833
24 417
+5 +1000
+12 +417
Recommend Efficiency(%)
capacitive(uF)
(Typ)
330 74
330 74
680 75
330 80
220 83
220 85
100 85
220 80
180 83
100 85
680 75
330 80
330 84
220 85
100 85
220 80
180 83
100 84
680 75
330 81
330 83
220 83
100 84
220 80
180 83
100 83
330 81
330 83
100 85
220 80
180 83
REV:15.1
Page 1 of 3
www.reicu.com
E-mail:service@reicu.com
ReICU
Input Characteristics
Parameter
Input Surge Voltage (1 sec. Max.)
Input Filter Type
DD(F)10 Series
Condition
5V Input Models
12V Input Models
24V Input Models
48V Input Models
110V Input Models
All Models
Min
-0.7
-0.7
-0.7
-0.7
-0.7
Typ Max
15
25
50
90
190
Internal Capacitor
Units
VDC
Output Characteristics
Parameter
Output Voltage Accuracy
Load regulation
Line regulation
Ripple and noise
Switching frequency
Transient Recovery Time
Short circuit Protection
Condition
+Vo
-Vo
10% 100% load
Vin(Min~Max)
BW=DC to 20MHz
Full load,nominal input
25% Load Step Change
Min Typ Max Units
1% %
2% 3% %
+0.5 +1
%
+0.1 +0.5 %
50 100 mVp-p
300 400 KHz
500 uS
Continuous,Automatic Recovery
General Characteristics
Parameter
Operating Temperature
Storage
Storage humidity
Cooling
Isolation voltage
Isolation resistance
MTBF
Case material
Condition
All output types
Free air convection
2mA 1minute
500VDC
2 105
Min
-40
-55
1000
1000
Typ Max
+85
+125
+95
Metal
Units
%
VDC
M
K hours
Temperature Derating Graph Curve
120
100 85
80
60
40 Safe Operating Area
20
0
-40 0 40 80 120
Operating Temperature( )
REV:15.1
Page 2 of 3
www.reicu.com
E-mail:service@reicu.com
ReICU
Design & Feature Considerations
1. Input/Output Ripple Reduction
Reduce output ripple, it is recommended to use capacitors at the input/output.
It is recommended to use 10uF~100uF capacitors at the input; 47~220uF capacitors at the output.
DD(F)10 Series
+Vin +Vo
Cin
DC/DC
Converter
Load
Cout
GND 0V
+Vin +Vo
Cout
Cin
DC/DC
Converter
0V
GND Cout
-Vo
Load
Load
2. Overload Protection
Tthe products provide protection against overload, the unit is equipped with internal current limiting circuitry .
Note
1.All the specifications typical at Ta=+25 resistive load, nominal input voltage and rated output current unless otherwise noted.
2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed.
3.Ripple & Noise measurement bandwidth is 0-20MHz.
3.Other input and output voltage may be available, please
4.To order the converter with 4:1 input voltage range, add letter F (e.g:DDF10-24S05) in the order code.
5.All DC/DC converters should be externally fused at the front end for protection.
6.Specifications subject to change without notice
Mechanical Dimension & Pin Connections
Bottom View
50.80(2.00)
10.16 10.16
(0.40) (0.40)
3
25.40 5.08
(1.00) (0.20)
2
4
1
5
10.16
(0.40)
10.16
(0.40)
Lateral View
6.35
(0.25)
10.16
(0.40)
1.00
(0.04)
Note:
Unit:mm(inch)
Pin 1 2 3 4 5
Single -Vin +Vin +Vo NP -Vo
Double -Vin +Vin +Vo COM -Vo