K3012P.pdf 데이터시트 (총 9 페이지) - 파일 다운로드 K3012P 데이타시트 다운로드

No Preview Available !

Optocoupler with Phototriac Output
K3010P(G) Series
Vishay Telefunken
Description
The K3010P(G) series consists of a phototransistor
optically coupled to a gallium arsenide infrared-emit-
ting diode in a 6-lead plastic dual inline package. The
elements are mounted on one leadframe using a
coplanar technique, providing a fixed distance be-
tween input and output for highest safety
requirements.
Applications
Circuits for safe protective separation against electri-
cal shock according to safety class II (reinforced
isolation):
D For appl. class I – IV at mains voltage 300 V
D For appl. class I – III at mains voltage 600 V
according to VDE 0884, table 2, suitable for:
14827
Monitors, air conditioners, line switches, solid
state relays, microwaves.
VDE Standards
These couplers perform safety functions according
to the following equipment standards:
D VDE 0884
Optocoupler for electrical safety requirements
D IEC 950/EN 60950
Office machines (applied for reinforced isolation
for mains voltage 400 VRMS)
D VDE 0804
Telecommunication apparatus and data
processing
D IEC 65
Safety for mains-operated electronic and related
household apparatus
Order Instruction
Ordering Code
CTR Ranking
K3010P/ K3010PG1)
< 15 mA
K3011P/ K3011PG1)
< 10 mA
K3012P/ K3012PG1)
< 5 mA
1) G = Leadform 10.16 mm; G is not marked on the body
~~
654
123
A (+) C (–) nc
Note: Pin 5 must not be connected
Remarks
Document Number 83504
Rev. A4, 13–Sep–99
www.vishay.de FaxBack +1-408-970-5600
1 (9)

No Preview Available !

K3010P(G) Series
Vishay Telefunken
Features
Approvals:
D BSI: BS EN 41003, BS EN 60095 (BS 415),
BS EN 60950 (BS 7002),
Certificate number 7081 and 7402
D FIMKO (SETI): EN 60950,
Certificate number 12398
D Underwriters Laboratory (UL) 1577 recognized,
file number E-76222
D VDE 0884, Certificate number 94778
VDE 0884 related features:
D Rated impulse voltage (transient overvoltage)
VIOTM = 6 kV peak
D Isolation test voltage (partial discharge test
voltage) Vpd = 1.6 kV
D Rated isolation voltage (RMS includes DC)
VIOWM = 600 VRMS (848 V peak)
D Rated recurring peak voltage (repetitive)
VIORM = 600 VRMS
D Creepage current resistance according to
VDE 0303/IEC 112
Comparative Tracking Index: CTI = 275
D Thickness through insulation 0.75 mm
General features:
D Isolation materials according to UL 94-VO
D Pollution degree 2 (DIN/VDE 0110 resp. IEC 664)
D Climatic classification 55/100/21 (IEC 68 part 1)
D Special construction:
Therefore, extra low coupling capacity of
typical 0.2 pF, high Common Mode Rejection
D IFT offered in 3 groups
D Coupling System C
Absolute Maximum Ratings
Input (Emitter)
Parameter
Reverse voltage
Forward current
Forward surge current
Power dissipation
Junction temperature
Test Conditions
tp 10 ms
Tamb 25°C
Symbol
VR
IF
IFSM
PV
Tj
Value
5
80
3
100
100
Unit
V
mA
A
mW
°C
Output (Detector)
Parameter
Off state output terminal voltage
On state RMS current
Peak surge current, non-repetitive
Power dissipation
Junction temperature
Test Conditions
tp 10 ms
Tamb 25°C
Symbol
VDRM
ITRMS
ITMS
PV
Tj
Value
250
100
1.5
300
100
Unit
V
mA
A
mW
°C
Coupler
Parameter
Test Conditions
Isolation test voltage (RMS)
t = 1 min
Total power dissipation
Ambient temperature range
Tamb 25°C
Storage temperature range
Soldering temperature
2 mm from case, t 10 s
1) Related to standard climate 23/50 DIN 50014
Symbol
VIO 1)
Ptot
Tamb
Tstg
Tsd
Value
3.75
350
–40 to +85
–55 to +100
260
Unit
kV
mW
°C
°C
°C
www.vishay.de FaxBack +1-408-970-5600
2 (9)
Document Number 83504
Rev. A4, 13–Sep–99

No Preview Available !

Electrical Characteristics (Tamb = 25°C)
Input (Emitter)
Parameter
Forward voltage
Junction capacitance
Test Conditions
IF = 50 mA
VR = 0, f = 1 MHz
Symbol
VF
Cj
K3010P(G) Series
Vishay Telefunken
Min. Typ. Max. Unit
1.25 1.6
V
50 pF
Output (Detector)
Parameter
Test Conditions
Forward peak off-state
voltage (repetitive)
IDRM = 100 nA
Peak on-state voltage
Critical rate of rise of
off-state voltage
ITM = 100 mA
IFT = 0, IFT = 30 mA
1) Test voltage must be applied within dv/dt ratings
Symbol Min. Typ. Max. Unit
VDRM 1)
250
V
VTM
(dv/dt)cr
(dv/dt)crq
0.1
1.5
10
0.2
3V
V/ms
V/ms
Coupler
Parameter
Emitting diode trigger
current
Test Conditions
Type
WVS = 3 V, RL = 150 K3010P(G)
K3011P(G)
K3012P(G)
Holding current
IF = 10 mA, VS 3 V
Note: IFT is defined as a minimum trigger current
Symbol
IFT
IFT
IFT
IH
Min.
Typ. Max. Unit
8 15 mA
5 10 mA
2 5 mA
100 mA
RS
Test condition:
dv/dtcr
VS = 2/3 VDRM
(Sine wave)
V~ RL = 33 k
IFT dv/dtcrq
RL
Veff = 30 V
(Sine wave)
RL = 2 k
95 10813
Figure 1. Test circuit for dv/dtcr and dv/dtcrp
Document Number 83504
Rev. A4, 13–Sep–99
www.vishay.de FaxBack +1-408-970-5600
3 (9)

No Preview Available !

K3010P(G) Series
Vishay Telefunken
yIF IFT
95 10814
IF = 0
dv / dtcrq
dv / dtcr
dv/dtcr
dv/dtcrq
Highest value of the “rate of rise of off-state voltage” which does not cause any switching from the
off-state to the on-state
Highest value of the “rate of rise of communicating voltage” which does not switch on the device again,
after the voltage has decreased to zero and the trigger current is switched from IFT to zero
Figure 2.
+5 V
270
0.1 µF
TTL
Galvanical separation
Figure 3. Motor control circuit
M
VAC ~
95 10815
www.vishay.de FaxBack +1-408-970-5600
4 (9)
Document Number 83504
Rev. A4, 13–Sep–99

No Preview Available !

K3010P(G) Series
Vishay Telefunken
Maximum Safety Ratings (according to VDE 0884) see figure 4
This device is used for protective separation against electrical shock only within the maximum safety ratings.
This must be ensured by using protective circuits in the applications.
Input (Emitter)
Parameters
Forward current
Output (Detector)
Test Conditions
Symbol
Isi
Value
130
Unit
mA
Parameters
Power dissipation
Coupler
Test Conditions
Tamb 25°C
Symbol
Psi
Value
600
Unit
mW
Parameters
Rated impulse voltage
Safety temperature
Test Conditions
Symbol
VIOTM
Tsi
Value
6
150
Unit
kV
°C
Insulation Rated Parameters (according to VDE 0884)
Parameter
Partial discharge test voltage –
Routine test
Partial discharge test voltage –
Lot test (sample test)
Insulation resistance
Test Conditions
100%, ttest = 1 s
tTr = 60 s, ttest = 10 s,
(see figure 5)
VIO = 500 V
VIO = 500 V,
Tamb = 100°C
VIO = 500 V,
Tamb = 150°C
(construction test only)
Symbol
Vpd
VIOTM
Vpd
RIO
RIO
RIO
VIOTM
675
600
Psi (mW)
525
450
375
300
225
150 Isi (mA)
VPd
VIOWM
VIORM
75
0
0
95 10925
25 50 75 100 125 150
Tamb ( °C )
0
13930
t1
Min. Typ. Max. Unit
1.6 kV
6 kV
1.3 kV
W1012
W1011
109 W
t1, t2 = 1 to 10 s
t3, t4 = 1 s
ttest = 10 s
tstres = 12 s
tTr = 60 s
t3 ttest t4
t2 tstres
t
Figure 4. Derating diagram
Figure 5. Test pulse diagram for sample test according to
DIN VDE 0884
Document Number 83504
Rev. A4, 13–Sep–99
www.vishay.de FaxBack +1-408-970-5600
5 (9)