D13007.pdf 데이터시트 (총 5 페이지) - 파일 다운로드 D13007 데이타시트 다운로드

No Preview Available !

www.DataSheet4US.ceomm iconductor
Features
High speed switching
High Collector Voltage : VCBO = 700V
Suitable for Switching Regulator and Motor Control
Ordering Information
Type NO.
STD13007F
Outline Dimensions
Marking
STD13007
STD13007F
NPN Silicon Power Transistor
Package Code
TO-220F
unit : mm
KST-H035-000
PIN Connections
1. Base
2. Collector
3. Emitter
1

No Preview Available !

Abwswow.lDuattaeShmeet4aUx.ciomm um ratings
Characteristic
Collector-Base voltage
Collector-Emitter voltage
Emitter-base voltage
Collector current (DC)
Collector current (Pulse)
Base current (DC)
Collector Power dissipation (Tc=25)
Junction temperature
Storage temperature
Symbol
VCBO
VCEO
VEBO
IC
ICM
IB
PC
Tj
Tstg
STD13007F
Rating
700
400
9
8
16
4
40
150
-55~150
(Ta=25°C)
Unit
V
V
V
A
A
A
W
°C
°C
Electrical Characteristics
Characteristic
Symbol
Test Condition
(Ta=25°C)
Min. Typ. Max. Unit
Collector-Emitter sustaining voltage BVCEO(sus) IC=10mA, IB=0
400 - - V
Emitter cut-off current
IEBO
VEB=9V, IC=0
- - 1 mA
DC Current gain
Collector-Emitter saturation voltage
Base-Emitter saturation voltage
hFE*
VCE(sat)*
VBE(sat)*
IC=2A, VCE=5V
IC=5A, VCE=5V
IC=2A, IB=0.4A
IC=5A, IB=1A
IC=8A, IB=2A
IC=2A, IB=0.4A
IC=5A, IB=1A
8 - 60
5 - 30
-- 1
-- 2V
-- 3
- - 1.2
V
- - 1.6
Transition frequency
Output capacitance
fT
VCE=10V, IC=0.5A, f=1MHz
-
Cob VCB=10V, IE=0, f=0.1MHz
-
14
80
- MHz
-
Turn on Time
Storage Time
Fall Time
ton
tstg
VCC=125V, IC=5A
IB1=-IB2=1A
tf
* Pulse test: PW300 , Duty cycle2%.
- - 1.6
- - 3
- - 0.7
KST-H035-000
2

No Preview Available !

Elwewcwt.rDiactaaSlheCet4hUa.cromacteristic Curves
Fig. 1 PC - TC
STD13007F
Fig. 2 VBE(sat) , VCE(sat) - IC
Fig. 3 hFE-IC
Fig. 4 tf , tstg - IC
Fig. 5 td , tr - IC
Fig. 6 Cob - VCB
KST-H035-000
3

No Preview Available !

wwwF.Diga.ta7SShaefeet4OU.pceormating Area
STD13007F
KST-H035-000
4

No Preview Available !

www.DataSheet4U.com
STD13007F
These AUK products are intended for usage in general electronic equipments(Office and
communication equipment, measuring equipment, domestic electrification, etc.).
Please make sure that you consult with us before you use these AUK products in equipm-
ents which require high quality and/or reliability, and in equipments which could have
major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic
signal, combustion central, all types of safety device, etc.).
AUK cannot accept liability to any damage which may occur in case these AUK products
were used in the mentioned equipments without prior consurtation with AUK.
KST-H035-000
5