U1600A.pdf 데이터시트 (총 9 페이지) - 파일 다운로드 U1600A 데이타시트 다운로드

No Preview Available !

Agilent U1600A Series
Handheld Digital Oscilloscopes
Data Sheet
Delivering the most functionality and
performance in their class of handheld
oscilloscope
Features
•Three-in-one solution : Dual
channel oscilloscope, True RMS
DMM and Real-Time Data Logger
•Large 4.5” color LCD display
•Up to 40 MHz bandwidth with
advanced triggering
•Up to 200 MSa/s sampling rate
•125 kilobytes/channel of waveform
memory depth
•6000 count DMM resolution with
22 automatic measurement
functions
•125 kilobytes/channel of waveform
memory depth
•11 built-in measurement functions
including voltmeter, ohmmeter and
auxiliary meter
•Dual Waveform Math functions
(additional FFT function with four
windowing techniques available in
U1604A)
•Full remote control and data
transfer via PC Link application
software
•USB 1.1 full speed interface
connectivity
•Multi-language Quick Help support
Introduction
The U1600A series handheld digital
oscilloscope has a 4.5-inch LCD
color display that is capable of
clearly distinguishing waveforms
between two channels. This
U1600A series offers a high
performance troubleshooting and
quality assurance tool for technical
professionals in the installation,
maintenance, service and
automotive industries. The U1600A
series consists of two models:
U1602A — 20 MHz oscilloscope and
U1604A — 40 MHz oscilloscope.
Each model has real time sampling
rate of up to 200 MSa/s. Users can
use the Dual Waveform Math
(DWM) and Fast Fourier Transform
(FFT) functions (in U1604A) to
perform quick waveform analysis
in both time and frequency
domains. The built-in 6000
resolution count true RMS digital
multimeter (DMM) comes with
auto-range feature that gives users
the flexibility to perform quick and
accurate meter measurement
functions inclusive of voltage,
resistance and auxiliary
measurements. In addition to this,
the U1600A series also comes
standard with data logging
functionality that allows users to
consolidate a sequence of data
points for data recording
purposes.
A scope, true RMS DMM and real-
time data logger in one instrument
The U1600A series is a robust,
high performance and reliable
handheld waveform and meter
measurement tool for today’s
challenging industrial environment.
This instrument not only provides
full featured oscilloscope
functions, but a 6000 count true
RMS DMM with real-time data
logger. The DMM consists of 11
measurement functions including
voltmeter (for DC voltage, AC
voltage, true RMS AC + DC voltage
measurements), ohmmeter (for 2-
wire resistance, capacitance, diode
and continuity test) and auxiliary
meter (for temperature, ampere,
humidity and pressure
measurements).
Free Datasheet http://www.datasheet-pdf.com/

No Preview Available !

Clearly distinguish your waveform
The U1600A series models
comes with a color display to
allow you to quickly and
clearly identify your signal
between two channels. The
large size LCD display – 4.5”
with 320 x 240 resolution
extends the simplicity and
makes it easier for you to see
more information.
Capture signal deviations, glitches
and dropouts effectively
The U1600A series offers the
best product specification for
users. This instrument provides
real-time sampling rate of up
to 200 MSa/s – 8 times the
sampling rate of competitive
handheld digital oscilloscope in
its class. Use U1600A series to
capture both instantaneous
and repetitive signal anomalies
effectively .
High precision zoom-in capability in
deep memory
Up to 250 times the memory
depth of competitive handheld
digital oscilloscope in this
class. With 125 kilobytes of
memory depth per channel,
now you can capture long
time spans and non-repeating
signals while maintaining a
maximum sampling rate of 200
MSa/s. Deep memory allows
you to quickly zoom in the
segment of interest and
uncover even the most subtle
details of the signal at a given
time base setting.
Isolate and analyze the signal you
want to see
The U1600A series comes with
flexible triggering capabilities
that allows you to isolate and
capture the condition you
want to characterize. The
advanced triggering includes
edge, pulse width, pattern and
video signal triggering that are
essential for quick isolation of
critical events.
Figure 1 High-definition of color resolution in large 4.5” LCD display allows you
to quickly distinguish and identify your signals and observe signal activity.
Before zoom
After zoom
Figure 2 With deep memory of 125 kilobytes per channel, use the zoom-in function
to magnify signal to the segment of your interest and scrutinize subtle details of
your signal.
2
Free Datasheet http://www.datasheet-pdf.com/

No Preview Available !

FFT (U1604A only) and Dual
Waveform Math functions for
waveform analysis
Besides the standard Dual
Waveform Math (DWM)
function in U1600A series, the
U1604A model is equipped
with an FFT (Fast Fourier
Transform) function. This
function allows you to view
the waveform in frequency
domain using four windowing
techniques (Rectangular,
Hanning, Hamming, Blackman-
Harris). Use the DWM function
to perform math functions for
signal addition and subtraction
from multiple channels.
Easy, straightforward connectivity
The U1600A series expands
the oscilloscope’s capability
with the PC Link application
software that caters for data
gathering, storage and
documentation needs from
instrument via USB 1.1 full
speed. You can control the
intstrument remotely from PC,
retrieve your waveform and
print it using a connected
printer. This PC Link
application software is bundled
with the purchase of any
U1600A series. As an option,
you can connect a USB flash
drive via the USB host port to
store your waveform and
configuration setup from the
instrument.
Built-in multi-lingual Quick Help
menu provides instant assistance
Need assistance while
operating the instrument? The
built-in multi-lingual Quick
Help menu helps to minimize
downtime in the event that
you need help to set up scope
and DMM functions. The
supported languages include
English, German, Italian,
Spanish, Portuguese, French,
Korean, Traditional Chinese,
Simplified Chinese and
Japanese.
Figure 3 The U1600A series comes equipped with DWM features, allowing you to
perform spectrum analysis and evaluate signal addition and subtraction from
multiple channels.
Figure 4 The U1600A series comes with a PC Link application software that
caters for data gathering, storage and documentation needs via USB full speed
remote control from PC.
3
Free Datasheet http://www.datasheet-pdf.com/

No Preview Available !

The U1600A Series Features
Oscilloscope Mode
The U1600A series handheld
digital oscilloscopes offers the
following standard and
advanced features to make
your analysis and
troubleshooting tasks easier
and faster.
Deep memory
The U1600A series comes
standard with 125 kilobytes of
memory depth, nearly 250
times the memory depth of
competitive handheld digital
oscilloscope in this class.
Autoscale
Autoscale enables the
instrument to quickly display
any active signals, and
automatically adjust the
vertical and horizontal settings
with trigger control for the
best signal display.
Dual Waveform Math (DWM) and
Fast Fourier Transform (FFT)
The U1600A series offers
analysis functions including
addition and subtraction for
DWM, as well as FFT with
four windowing techniques
(Rectangular, Hanning,
Hamming and Blackman-
Harris). FFT functions is only
available for the U1604A
model.
Cursor measurement
Use cursor function to
manually or automatically
place readout of the
waveform’s voltage at any
desired vertical or horizontal
point.
22 automatic measurements
Up to 22 automatic available
measurements. You can make
and display four different
measurements simultaneously.
Advanced triggering
Advanced triggering includes
edge, pulse width, pattern and
video to help you isolate the
signal you want to see.
Easy connectivity
The PC Link application
software is bundled with the
purchase of any U1600A series
handheld digital oscilloscope.
This software provides
flexibility for data gathering,
storage and documentation
needs via USB connectivity.
USB flash drive is also
available to you as an option
to save and retrieve
configuration setups or
waveforms to and from the
USB flash drive.
Save and recall waveform and setup
memories
Up to 10 waveforms and
configuration setups can be
stored and recalled at anytime
for future use and reference.
Logger mode
The U1600A series allows you
to customize your data logging
for any DMM measurement.
This sophiscated function
allows you to record and
consolidate a sequence of data
points for data plotting
purposes.
Digital Multimeter (DMM)
Mode
Auto-range
All meter measurements come
in auto-range mode –
instrument will auto-select the
most appropriate range for
measurement.
Voltmeter
Voltmeter measurement
includes DC voltage, AC voltage
and AC+DC voltage with auto -
measurement of minimum,
maximum and average value.
Ohmmeter
Ohmmeter measurement
consists of resistance,
capacitance , diode test and
continuity test. The auto -
measurement of minimum,
maximum and average value
applies only to resistance and
continuity test.
Auxiliary meter
Auxiliary meter involves
temperature, ampere, humidity
and pressure measurements.
Similary, the auto -
measurement of minimum,
maximum and average value is
also available in this mode.
4
Free Datasheet http://www.datasheet-pdf.com/

No Preview Available !

SCOPE SPECIFICATIONS[1]
Vertical System : Scope Channels
Bandwidth (–3 dB)
U1602A : DC to 20 MHz
U1604A : DC to 40 MHz
DC Vertical Gain Accuracy
5 mV/div: ± 4% full scale
10 mV/div to 100 V/div: ± 3% full scale
Scope Channel Triggering
Trigger Sensitivity
DC to 50 MHz: 0.5 divisions
U1602A: 5 MHz to 20 MHz — 1 division
U1604A: 5 MHz to 40 MHz — 1 division
SCOPE CHARACTERISTICS[2]
Acquisition : Scope Channels
Maximum Sampe Rate
U1602A : 200 MSa/s interleaved, 100 MSa/s each channel (50 s/div to 125 ns/div)
U1604A : 200 MSa/s interleaved, 100 MSa/s each channel (50 s/div to 250 ns/div)
Equivalent Sample Rate
U1604A : 2.5 GSa/s (125 ns/div to 10 ns/div)
Vertical Resolution
8 bits
Maximum Memory Depth
125 kilobytes/channel
Peak Detection
5 ns
Average
Selectable in average number of 2, 4, 8, 16, 32, 64, 128, 256
Vertical System : Scope Channels
Analog Channels
Bandwidth (–3 dB)
AC coupled
Rise time
Single shot bandwidth
Range
Maximum input
Offset/Dynamic range
Input impedance
Coupling
Probes
Probe attenuation factors
Coupling
Maximum probe input
Noise peak-to-peak
DC vertical offset accuracy
Single cursor accuracy
Dual cursor accuracy
Channel 1 and Channel 2 simultaneous acquisition
U1602A : DC to 20 MHz
U1604A : DC to 40 MHz
< 10 Hz without probe
U1602A : < 17 ns
U1604A : < 8 ns
U1602A : 20 MHz
U1604A : 40 MHz
5 mV/div to 100 V/div
CAT III 300 Vrms
± 5 div
1 MW || < 20 pF
AC, DC, GND
U1560-60001 : 500 MHz 1:1 passive probe
U1561-60001 : 500 MHz 10:1 passive probe
1x, 10x, 100x
3 Vp-p, ~ 1 kHz
1x CAT III 300 VAC
10x, 100x CAT III 600 VAC
3% of full scale or 5 mV, whichever is greater
±0.1 div ±2 mV ±0.5% offset value
4% full scale
4% full scale
[1] All specifications are warranted. Specifications are valid after a 30 minutes warm-up period and within ± 10 oC from firmware
calibration temperature.
[2] All characteristics are typical performance values and are not warranted. Characteristics are valid after a 30 minutes warm-up
period and within ± 10 oC from firmware calibration temperature.
5
Free Datasheet http://www.datasheet-pdf.com/