AGN20024.pdf 데이터시트 (총 4 페이지) - 파일 다운로드 AGN20024 데이타시트 다운로드

No Preview Available !

GNTESTING
ULTRA-SMALL PACKAGE
GN-RELAYSSLIM POLARIZED RELAY
10.60±0.3
.417±.012
5.70±0.3
.224±.012
9.00±0.3
.354±.012
10.60±0.3
.417±.012
5.70±0.3
.224±.012
Max.10.00
.394
mm inch
FEATURES
• Compact slim body saves space
Thanks to the small surface area of 5.7
mm × 10.6 mm .224 inch × .417 inch and
low height of 9.0 mm .354 inch, the pack-
aging density can be increased to allow
for much smaller designs.
• Outstanding surge resistance.
Surge withstand between open contacts:
1,500 V 10×160 µs (FCC part 68)
Surge withstand between contacts and
coil: 2,500 V 2×10 µs (Bellcore)
• The use of twin crossbar contacts en-
sures high contact reliability.
AgPd contact is used because of its good
sulfide resistance. Adopting low-gas
molding material. Coil assembly molding
technology which avoids generating vola-
tile gas from coil.
• Increased packaging density
Due to highly efficient magnetic circuit de-
sign, leakage flux is reduced and changes
in electrical characteristics from compo-
nents being mounted close-together are
minimized. This all means a packaging
density higher than ever before.
• Nominal operating power: 140 mW
• Outstanding vibration and shock re-
sistance.
Functional shock resistance:
750 m/s2 {75G}
Destructive shock resistance:
1,000 m/s2 {100G}
Functional vibration resistance:
10 to 55 Hz (at double amplitude of 3.3
mm .130 inch)
Destructive vibration resistance:
10 to 55 Hz (at double amplitude of 5 mm
.197 inch)
SPECIFICATIONS
Contact
Arrangement
2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1A )
100 m
Contact material
Stationary: AgPd+Au clad
Movable: AgPd
Nominal switching capacity
(resistive load)
1 A 30 V DC
0.3 A 125 V AC
Rating
Max. switching power
(resistive load)
Max. switching voltage
30 W, 37.5 V A
110 V DC, 125 V AC
Max. switching current
Min. switching capacity f1
1A
10 µA 10 mV DC
Nominal
operating
power
Single side stable
1 coil latching
140mW (1.5 to 12 V DC)
230mW (24 V DC)
100mW (1.5 to 12 V DC)
120mW (24 V DC)
Mechanical (at 180 cpm)
5 × 107
Expected
life (min.
operations)
Electrical
(at 20 cpm)
1 A 30 V DC
resistive
0.3 A 125 V AC
resistive
105
105
Remarks:
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section.
*2 Detection current: 10mA.
*3 Nominal voltage applied to the coil, excluding contact bounce time.
*4 By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
*5 Half-wave pulse of sine wave: 6 ms; detection time: 10µs.
*6 Half-wave pulse of sine wave: 6 ms.
*7 Detection time: 10µs.
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
Characteristics
Initial insulation resistance*1
Min. 1,000M(at 500V DC)
Initial
breakdown
voltage*2
Between open contacts
Between contact sets
Between contacts and coil
750 Vrms for 1min.
1,000 Vrms for 1min.
1,500 Vrms for 1min.
Initial surge
voltage
Between open contacts
(10×160 µs)
Between contacts and coil
(2×10 µs)
1,500 V (FCC Part 68)
2,500 V (Bellcore)
Operate time [Set time]*3 (at 20°C)
Max. 4 ms (Approx. 2 ms)
[Max. 4 ms (Approx. 2 ms)]
Release time (without diode)
[Reset time]*3 (at 20°C)
Max. 4 ms (Approx. 1 ms)
[Max. 4 ms (Approx. 2 ms)]
Temperature rise*4 (at 20°C)
Max. 50°C
Shock resistance
Functional*5
Destructive*6
Min. 750 m/s2{75G]
Min. 1,000 m/s2{100G]
Vibration resistance
Functional*7
Destructive
10 to 55 Hz at double
amplitude of 3.3 mm
10 to 55 Hz at double
amplitude of 5 mm
Conditions for opera- Ambient
tion, transport and temperature f2
storage*8
(Not freezing and con-
densing at low tem- Humidity
perature)
–40°C to 85°C
–40°F to 185°F
5 to 85% R.H.
Unit weight
Approx. 1 g.035 oz
Notes:
f1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
f2 The upper limit for the ambient temperature is the maximum temperature that
can satisfy the coil temperature rise. Under the packing condition, allowable
temperature range is from –40 to +70°C –40° to +158°F.
125

No Preview Available !

GN
TYPICAL APPLICATIONS
• Telephone exchange, transmission
equipment
• Communications devices
• Measurement devices
• Home appliances, and audio/visual
equipment
• Handheld and portable products
ORDERING INFORMATION
Ex. AGN 2 0 0 A 1 H Z
Contact arrangement Operating function Type of operation
Terminal shape
Coil voltage (DC)
Packing style
2: 2 Form C
0: Single side stable 0: Standard type
1: 1 coil latching
(B.B.M.)
Nil: Standard PC board terminal
A: Surface-mount terminal A type
S: Surface-mount terminal S type
1H: 1.5V
03 : 3V
4H: 4.5V
06 : 6V
09 : 9V
12 : 12V
24 : 24V
Nil: Tube packing
Z: Tape and reel packing
(piked from 5/6/7/8
pin side)
Note: Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available. Suffix “X” instead of “Z”.
TYPES AND COIL DATA (at 20°C 68°F)
(1) Standard PC board terminal
Operating
Function
Single side
stable
Part No.
Standard PC
board terminal
Coil Rating,
V DC
AGN2001H
AGN20003
AGN2004H
AGN20006
AGN20009
AGN20012
AGN20024
1.5
3
4.5
6
9
12
24
Pick-up volt-
age, V DC
(max.)
(initial)
1.13
2.25
3.38
4.5
6.75
9
18
Drop-out
voltage,
V DC (min.)
(initial)
0.15
0.3
0.45
0.6
0.9
1.2
2.4
Nominal
operating
current,
mA (±10%)
93.8
46.7
31
23.3
15.5
11.7
9.6
Coil resistance,
(±10%)
16
64.2
145
257
579
1,028
2,504
Nominal
operating
power, mW
140
140
140
140
140
140
230
Max. allowable
voltage,
V DC
2.25
4.5
6.75
9
13.5
18
28.8
Operating
Function
Part No.
Standard PC
board terminal
Coil Rating,
V DC
1 coil latching
AGN2101H
AGN21003
AGN2104H
AGN21006
AGN21009
AGN21012
AGN21024
1.5
3
4.5
6
9
12
24
Set voltage,
V DC (max.)
(initial)
1.13
2.25
3.38
4.5
6.75
9
18
Reset voltage,
V DC (max.)
(initial)
1.13
2.25
3.38
4.5
6.75
9
18
Nominal
operating
current,
mA (±10%)
66.7
33.3
22.2
16.7
11.1
8.3
5.0
Coil resistance,
(±10%)
22.5
90
202.5
360
810
1,440
4,800
Nominal
operating
power, mW
100
100
100
100
100
100
120
Max. allowable
voltage,
V DC
2.25
4.5
6.75
9
13.5
18
36
1) Standard packing: 50 pcs. in an inner package (tube); 1,000 pcs. in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
(2) Surface-mount terminal
Operating
Function
Part No.
Tube packing
Tape and reel
packing
Coil Rating,
V DC
Pick-up
voltage,
V DC (max.)
(initial)
Drop-out
voltage,
V DC (min.)
(initial)
Nominal
operating
current,
mA (±10%)
Coil
resistance,
(±10%)
AGN200r1H AGN200r1HZ
1.5
1.13 0.15 93.8
16
AGN200r03 AGN200r03Z
3
2.25 0.3 46.7 64.2
Single side
stable
AGN200r4H
AGN200r06
AGN200r09
AGN200r4HZ
AGN200r06Z
AGN200r09Z
4.5
6
9
3.38 0.45 31 145
4.5 0.6 23.3 257
6.75 0.9 15.5 579
AGN200r12 AGN200r12Z
12
9
1.2 11.7 1,028
AGN200r24 AGN200r24Z
24
18
2.4 9.6 2,504
r: For each surface-mounted terminal variation, input the following letter.
A type: A, S type: S
1) Standard packing: 50 pcs.(tube), 500pcs. (tape and reel)in an inner package; 1,000 pcs. in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
Nominal
operating
power,
mW
140
140
140
140
140
140
230
Max.
allowable
voltage,
V DC
2.25
4.5
6.75
9
13.5
18
28.8
126

No Preview Available !

GN
Operating
Function
Part No.
Tube packing
Tape and reel
packing
Coil Rating,
V DC
Set voltage,
V DC (max.)
(initial)
Reset
voltage,
V DC (max.)
(initial)
Nominal
operating
current,
mA (±10%)
Coil
resistance,
(±10%)
AGN210r1H AGN210r1HZ
1.5
1.13 1.13 66.7 22.5
AGN210r03 AGN210r03Z
3
2.25 2.25 33.3
90
1 coil
latching
AGN210r4H
AGN210r06
AGN210r09
AGN210r4HZ
AGN210r06Z
AGN210r09Z
4.5
6
9
3.38 3.38 22.2 202.5
4.5 4.5 16.7 360
6.75 6.75 11.1 810
AGN210r12 AGN210r12Z
12
9
9 8.3 1,440
AGN210r24 AGN210r24Z
24
18
18 5.0 4,800
r: For each surface-mounted terminal variation, input the following letter.
A type: A, S type: S
1) Standard packing: 50 pcs.(tube), 500pcs. (tape and reel)in an inner package; 1,000 pcs. in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
Nominal
operating
power,
mW
100
100
100
100
100
100
120
Max.
allowable
voltage,
V DC
2.25
4.5
6.75
9
13.5
18
36
DIMENSIONS
1. PC board terminal
10.60±0.3
.417±.012
5.70±0.3
.224±.012
0.40±0.1
.016±.004
(1.50)
(.059)
(0.50) 9.00±0.3
(.020) .354±.012
2.20±0.15
.087±.006
3.20±0.15
.126±.006
3.50±0.3
.138±.012
0.25±0.1
.010±.004
3.20±0.15
.126±.006
PC board pattern
3.20
.126
7.60
.299
3.20
.126
2.20
8-0.85 dia. .087
8-.033 dia
Tolerance: ±0.1 ±.004
mm inch
Schematic (Bottom view)
Single side stable
(Deenergized condition)
1 coil latching
(Reset condition)
1 234
1 234
8 765
Direction indication
8 765
Direction indication
2. Surface-mount terminal
1) A type
10.60±0.3
.417±.012
5.70±0.3
.224±.012
0.25±0.1
.010±.004
0.40±0.1
.016±.004
(1.50)
(.059)
(0.50)
(.020)
9.00±0.3
.354±.012
Max. 10.00
.394
2.20±0.15
.087±.006
3.20±0.15
.126±.006
3.20±0.15
.126±.006
7.40±0.3
.291±.012
Suggested mounting pad
3.20
.126
2.20
.087
3.10
.122
5.30
.209
0.80
.031
Tolerance: ±0.1 ±.004
Schematic (Top view)
Single side stable
(Deenergized condition)
1 coil latcing
(Reset condition)
8 765
8 765
1 234
Direction indication
1 234
Direction indication
1) S type
10.60±0.3
.417±.012
5.70±0.3
.224±.012
0.25±0.1
.010±.004
0.40±0.1
.016±.004
(1.50)
(.059)
(0.50)
(.020)
9.00±0.3
.354±.012
Max.
10.00
.394
2.20±0.15
.087±.006
3.20±0.15
.126±.006
3.20±0.15
.126±.006
5.70±0.3
.224±.012
Suggested mounting pad
3.20
.126
2.25
.089
2.20
.087
4.45
.175
0.80
.031
Tolerance: ±0.1 ±.004
REFERENCE DATA
1. Max. switching capacity
DC resistive load
AC resistive load
1.0
0.3
2. Life curve
100
50
40
30
20
10
DC 30V resistive load
AC 125V
resistive load
30 100
Contact voltage, V
0
0.2 0.4 0.6 0.8 1.0 1.2
Switching current, A
127

No Preview Available !

GN
NOTES
1. Coil operating power
1) As a general rule, only a pure DC pow-
er supply should be used for the coil drive.
2) To ensure proper operation, the voltage
applied to both terminals of the coil should
be ±5% (at 20°C 68°F) the rated operating
voltage of the coil. Also, be aware that the
pick-up and drop-out voltages will fluctu-
ate depending on the ambient tempera-
ture and operating conditions.
3) The ripple factor for the voltage applied
to the coil should be less than 5%.
4) For set and reset latching relays, the
rated operating voltage should be applied
to the coil for 10 ms or more.
2. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or mal-
function.
3. External magnetic field
Since GN relays are highly sensitive po-
larized relays, their characteristics will be
affected by a strong external magnetic
field. Avoid using the relay under that con-
ditions.
4. Cleaning
In automatic cleaning, cleaning with the
boiling method is recommended. Avoid ul-
trasonic cleaning which subjects the relay
to high frequency vibrations. It may cause
the contacts to stick.
lt is recommended that a fluorinated hy-
drocarbon or other alcoholic solvent be
used.
5. Packing style
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
Orientation (indicates PIN No.1)stripe
Stopper (green)
Stopper (red)
2) Tape and reel packing
(A type)
(1)-1 Tape dimensions
mm inch
Relay polarity bar
(Z type)
0.40
1.50
+0.1
0
dia
.059
+.004
0
dia
.016
4.00
.157
2.00
.079
11.50
.453
1.75
.069
24.00±0.3
11.10 .945±.012
.437
10.70±0.2
.421±.008
GN relays
2.00dia
.079dia
16.00
.630
8.00
.315
Tape coming out direction
General tolerance ±0.1 mm .004 inch
(S type)
(1)-2 Tape dimensions
Relay polarity bar
(Z type)
2.00
1.50
+0.1
0
dia
.079
.059
+.004
0
dia
4.00 2.0dia
.157 .079dia
1.75
.069
10.70±0.2
.421±.008
0.40
.016
11.50
.453 24.00±0.3
11.10 .945±.012
.437
GN relays
16.00
6.3
.630 .248
Tape coming out direction
General tolerance ±0.1 mm .004 inch
(2) Dimensions of plastic peel
mm inch
21±0.8 dia.
.827±.031 dia.
2.0±0.5
.079±.020
100±1 dia.
3.937±.039 dia.
370±2 dia.
14.567±.079 dia.
13±0.2 dia.
.512±.008 dia.
24.4
+2
0
.961
+.079
0
2.0±0.2
.079±.008
6. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
C
A
B
Please chuck the portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
91/12/82000
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog